specification ts-400-112 ts-400 -124 ts-400 -148 ts-400 -212 ts-400 -224 ts-400 -248 20a 0.63a 21 ~ 30vdc 86% 75 5 10a 0.32a 42 ~ 60vdc 87% 70 5 20a 0.63a 21 ~ 30vdc 87.5% 75 5 10a 0.32a 42 ~ 60vdc 88.5% 70 5 model ac voltage maximum output power waveform output frequency ac regulation typ. voltage range (typ.) efficiency (typ.) note.1 dc current (typ.) input input battery output environment fuse safety & emc bat. low alarm bat. low shutdown over temperature output short bat. polarity gfci proctection protection protection true sine wave (thd<3%) at rated input voltage 40a 1.25a 10.5 ~ 15vdc 86% 85 5 40a*2 40a*1 20a*1 20a*1 40a*1 3.0%, at rated input voltage 10.5 ~ 15vdc 84.5% 40a 1.25a 40a*2 85 5 protection type : shut down o/p voltage, re-power on to recover ; by internal rth1 detect power transistor protection type : shut down o/p voltage, re-power on to recover by internal fuse open optional (only type f) none emi conduction&radiation ems immunity compliance to fcc class a none working temp. working humidity storage temp., humidity safety standards -10 ~ +40 @ 100% load ; +60 @ 50% load 20% ~ 90% rh non-condensing -30 ~ +70 / -22 ~ +158 f, 10 ~ 95% rh o design refer to ul458 none compliance to en61000-4-2,3,8 env50204 compliance to en55022 class a, 72/ 245/ cee, 95/ 54/ ce, e-mark true sine wave output (thd<3%) thermostatically controlled cooling fan front panel indicator for operation status power on-off switch protections: bat. low alarm / bat. low shutdown / over voltage / over temp. / output short / input reverse polarity / overload application : home appliance, power tools, office and portable equipment, vehicle and yacht ...etc. 2 years warranty high surge power up to 800w high efficiency up to 88.5% built-in remote on-off control rated power 400w over load (typ.) 105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec. protection type : shut down o/p voltage, re-power on to recover withstand voltage isolation resistance bat i/p - ac o/p:3.0kvac ac o/p - fg:1.5kvac bat i/p-ac o/p, ac o/p-fg:100m ohms / 500vdc / 25 / 70% rh vibration 10 ~ 500hz, 3g 10min./1cycle, 60min. each along x, y, z axes features : others packing 1.73kg; 6pcs/11.4kg/1.55cuft dimension 205*158*67mm (l*w*h) note 1.efficiency is tested by 300w, linear load at 12v/24v/48v input voltage. 2.all parameters not specified above are measured at rated load, 25 of ambient temperature. 460w for 180 sec. / 600w for 10 sec. / surge power 800w for 30 cycles(typ.) 11.3 4 % 22.5 4 % 45 4 % 45 4 % 22.5 4 % 10.5 4 % 21 4 % 42 4 % 42 4 % 21 4 % 11.3 4% 10.5 4 % t s - 4 0 0 s e r i e s file name:ts-400-spec 2009-07-22 50 0.1hz 50/60hz selectable by setting button 60 0.1hz 50/60hz selectable by setting button front panel indicator operation status ; green : normal, orange(flashing) : remote control of f, red : abnormal 24v 48v 24v 48v bat. voltage 12v 12v no load current draw typ. off mode draw current 1ma battery types open & sealed lead acid 400w true sine wave dc-ac power inverter lvd none en60950-1 100 / 110 / 115 / 120vac selectable by setting button s.w factory setting set at 110vac 200 / 220 / 230 / 240vac selectable by setting button s.w factory setting set at 230vac e 13 remote control open : normal work ; short : remote off function
mechanical specification _ _ _ environment temperature ( ) derating curve unit:mm file name:ts-400-spec 2009-07-22 t s - 4 0 0 s e r i e s true sine wave inverter 12:12vdc 24:24vdc bat. voltage: 48:48vdc 1:110vac 2:230vac output: o/p wattage:400w ts 400 112 a 400w true sine wave dc-ac power inverter a :type b :type c :type d :type e :type f :type ab c d e f outlet outlet outlet outlet outlet outlet 120 205 ac output status setting ac output status setting 147 158 9 7 11 8.9 direction air flow 18 12 42.5 type-a type-b 25.32 chassis ground r.c on off 10.7 67 reverse polarity will damage the unit. type-a receptacle type country certificate type-b type-c type-d type-e type-f usa europe australia u.k japan gfci ac output receptacles (optional) e 13 e e 13 13 load (%) -10 10 20 30 40 50 60 70 (horizontal) 20 40 50 60 80 100 0
|